1. |
Turn ignition switch OFF and disconnect the negative
(-)battery cable.
|
2. |
Remove the fuel pump assembly.
|
3. |
Check motor operation by fuel pump connector (A)
connecting power(No.2) and ground(No.4)
|
1. |
Using an ohmmeter, measure the resistance between
terminals 1 and 3 of sender connector (A) at each float level.
|
2. |
Also check that the resistance changes smoothly when
the float is moved from "E" to "F".
|
Purge Control Solenoid
Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake manifold.
It is a solenoid valve and is open when ...
Description and Operation
Operation and Leakage Check
Check all of the following items:
Component
Procedure
Brake Booster (A)
Check brake operation by applyin ...
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the oil temperature sensor connector.
3.
Measure resistance between ...