Back-up Lamp Switch. Specifications
Specifications
1.
Working voltage: DC 10~15V
2.
Operating force: 3.0kg Max.
3.
Voltage drop: - 0.4V
...
Removal
1.
Disconnect the battery negative cable, and wait for at least three
minutes before beginning work.
2.
Remove the front seat assembly.
...
Camshaft Position Sensor
(CMPS). Description and Operation
Description
Camshaft Position Sensor (CMPS) is a hall sensor and detects
the camshaft position by using a hall element.
It is related with Crankshaft Position Sensor (CKPS) and
detects t ...