1. |
Disconnect the battery negative terminal.
|
2. |
Remove the air duct and air cleaner assembly. (Refer
to EM group)
|
3. |
Disconnect the starter cable (B) from the B terminal
on the solenoid then disconnect the connector (A) from the S terminal.
|
4. |
Remove the 2 bolts holding the starter, then remove
the starter (A).
|
5. |
Installation is the reverse of removal.
|
6. |
Connect the battery negative terminal last.
|
Emergency starting
Connect cables in numerical order and disconnect in reverse order. ...
Oil Pump. Components and Components
Location
Components
1. Timing chain cover
2. Inner roter
3. Outer roter
4. Pump cover
5. Gasket
6. Oil screen
7. Oil pan
8. Drain plug gasket
9. Oil drain pl ...
Tightening Torques
Item
kgf.m
N.m
lb-ft
Positive crankcase ventilation valve installation
0.8 ~ 1.2
7.8 ~ 11.8
5.8 ~ 8.7
...