Inspection
1. |
Disconnect the vapor hose from the intake manifold
and connect a vacuum pump to the nipple on the intake manifold.
· At Cold Engine [Engine Coolant Temperature < 60°C(140°F)]
|
2. |
Check the following points with applied vacuum at
the purge control solenoid valve (PCSV).
· At Warmed Engine [Engine Coolant Temperature. 80°C(176°F)]
|
1. |
Turn ignition switch OFF and disconnect the negative
(-) battery cable.
|
2. |
Disconnect the PCSV connector (A).
|
3. |
Disconnect the vapor hose (B) which is connected
to the intake manifold from the PCSV.
|
4. |
After connecting a vacuum pump to the nipple, apply
vacuum.
|
5. |
With the PCSV control line grounded, check the valve
operation with battery voltage applied to the PCSV(Open) and removed(Closed).
|
6. |
Measure the coil resistance of the PCSV.
|
1. |
Select "Evap. Leakage Test".
|
2. |
Proceed with the test according to the screen introductions.
|
Repair procedures
Inspection
1.
After disconnecting the vapor hose from the PCV valve,
remove the PCV valve.
2.
Reconnect the PCV valve to the vapor hose.
...
Care of seat belts
Seat belt systems should never be disassembled or modified. In addition, care
should be taken to assure that seat belts and belt hardware are not damaged by seat
hinges, doors or other abuse.
WAR ...
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the oil temperature sensor connector.
3.
Measure resistance between ...