Hyundai Accent: Body Control Module (BCM). SpecificationsSpecifications
|
Item |
Requirement |
Remark |
|
Rated voltage |
DC 12V |
Shall activate normally in these range. |
|
Operating voltage range |
DC 9 ~ 16V |
|
|
Operating temperature range |
-30°C ~ +75°C (-22°F ~ +167°F) |
|
|
Storage temperature range |
-40°C ~ +85°C (-40°F ~ +185°F) |
|
|
Max humidity in use |
95% |
|
|
High voltage resistance |
24V |
|
|
Insulation resistance |
100MΩ or more (measured with 500V MEGGER) |
Specify as well as parts that insulation like PCB, moisture-proof
COATING is required |
|
Dark Current |
Max 4mA |
Measure when the state, all output loads are OFF and there are no
Input SW(including TX operation) changes, continues 2sec. |
|
Voltage drop |
1.2V or less |
Output terminals for POWER WINDOW RELAY shall be 2.0V or less |
|
NO |
System name |
Capacity |
|
1 |
Room lamp |
DC 12V 20W(Lamp load) |
|
2 |
Power door relay |
DC 12V 200mA(Inductive load) |
|
3 |
Hazard relay |
DC 12V 200mA(Inductive load) |
|
4 |
Door lock relay |
DC 12V 200mA(Inductive load) |
|
5 |
Door unlock relay |
DC 12V 200mA(Inductive load) |
|
6 |
Driver door unlock relay |
DC 12V 200mA(Inductive load) |
|
7 |
Tail lamp relay |
DC 12V 200mA(Inductive load) |
|
8 |
Horn relay |
DC 12V 200mA(Inductive load) |
|
9 |
Interior autocut |
DC 12V 200mA(Inductive load) |
Removal
1.
Disconnect the battery negative cable, and wait for at least three
minutes before beginning work.
2.
Remove the front seat assembly.
...
Special Service Tools
Special Service Tools
Item
Illustration
Application
Fuel Pressure Gauge
(09353-24100)
Measuring the fuel line press ...
Inspection
1.
Check the signal waveform of the CMPS and CKPS using
the GDS.
Specification:
Refer to “Wave Form”
...