1. |
Install the valves.
|
2. |
Using the SST(09222 - 3K000, 09222 - 3K100), compress
the spring and install the retainer locks.
After installing the valves, ensure that the retainer
locks are correctly in place before releasing the valve spring compressor.
|
3. |
Lightly tap the end of each valve stem two or three
times with the wooden handle of a hammer to ensure proper seating of
the valve and retainer lock.
|
4. |
Install the MLA(Mechanical lash adjuster)s.
Check that the MLA (A) rotates smoothly by hand.
|
Installation
1.
Installation is reverse of removal.
PCV Valve installation:
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7
lb-ft)
...
Troubleshooting
Troubleshooting
1.
The lamp switch inputs can be checked using the GDS.
2.
To check the input value of lamp switch, select option "Body Co ...
Specifications
Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
22.0 ~ 26.0 [20°C(68°F)]
...