Hyundai Accent: SpecificationsSpecifications
|
Items |
Specification |
|
|
Ignition coil |
Primary resistance |
0.7 ± 15 % (Ω) |
|
Secondary resistance |
5.9 (kΩ) |
|
|
Spark plugs |
Type |
SILZKR6B10E |
|
Gap |
1.0 ~ 1.1 mm (0.0394 ~ 0.0433in.) |
|
|
Items |
Specification |
||
|
Starter |
Rated voltage |
12V, 0.9kW |
|
|
No. of pinion teeth |
8 |
||
|
No-load characteristics |
Voltage |
11.5V |
|
|
Ampere |
60A, MAX |
||
|
Speed |
5,500rpm, MIN |
||
|
Items |
Specification |
||
|
Alternator |
Rated voltage |
13.5V, 90A |
|
|
Speed in use |
1,000 ~ 18,000rpm |
||
|
Voltage regulator |
IC Regulator built-in type |
||
|
Regulator setting voltage |
External mode |
ECU control |
|
|
Internal mode |
14.55 ± 0.3V |
||
|
Temperature compensation |
External mode |
ECU control |
|
|
Internal mode |
-3.5 ± 2mV / °C |
||
|
Battery |
Type |
36 - 20 GL |
|
|
Cold cranking amperage |
410A |
||
|
[at -18°C (-0.4°F)] |
|||
|
Reserve capacity |
80min |
||
|
Specific gravity [at 25°C(77°F)] |
1.280 ± 0.01 |
||
|
TroubleshootingSchematic Diagrams
Circuit Diagram
...
Overdrive Clutch Control Solenoid Valve(OD/C_VFS). Description and Operation
Description
Overdrive clutch control solenoid valve(OD/C_VFS) is attached to the valve
body. This variable force solenoid valve directly controls the hydraulic pressure
inside the overdrive ...
To resume cruising speed at more than approximately 25 mph (40 km/h)
If any method other than the cruise ON/OFF switch was used to cancel cruising
speed and the system is still activated, the most recent set speed will automatically
resume when the RES+ switch is ...