Warning Lamp Activation
Warning Lamp Behavior after Ignition On |
1. |
Active faults exist.
|
2. |
No active faults or crash records exists.
|
3. |
When turning the ignition switch ON during variant coding (EOL)
mode, the airbag warning lamp is turned on and blinks at intervals of
1 second till the coding is completed.
In case the variant coding is normally completed, the airbag warning
lamp is turned on for 6 seconds, and then turned off. Otherwise the
airbag warning lamp continuously blinks at intervals of 1 second.
When there is active fault in airbag system or SRSCM internal
fault, the variant coding (EOL) can’t be completed. In this case, do
the variant coding (EOL) procedure again after troubleshooting with
the GDS.
|
1. |
Loss of battery supply to the SRSCM : warning lamp turned on continuously.
|
2. |
Loss of internal operating voltage : warning lamp turned on continuously.
|
3. |
Loss of Microprocessor operation : warning lamp turned on continuously.
|
4. |
SRSCM not connected : warning lamp turned on continuously.
|
Installation
1.
Connect the audio unit connectors and cable.
2.
Install the audio unit.
3.
Install the crash pad center fas ...
Torque Converter Control Solenoid Valve (T/CON_VFS). Description and Operation
Description
Torque converter control solenoid valve (T/CON_VFS) is attached to the
valve body. This variable force solenoid valve directly controls the hydraulic
pressure inside the torque c ...
Inspection
1.
Check the components for damage or deformation.
2.
Compress and extend the piston and check that there is no abnormal
resistance or unus ...