Hyundai Accent Manuals

Hyundai Accent: Line Pressure Control Solenoid Valve. Specifications - Automatic Transaxle Control System - Automatic Transaxle SystemHyundai Accent: Line Pressure Control Solenoid Valve. Specifications

Specifications

Direct control VFS[LINE Pressure]
▷ Control type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
500.14 ~ 9.81
(5.4 ~ 0.1, 7.68 ~ 1.42)
Current value(mA)
50 ~ 850
 Internal resistance(Ω)
5.1


Line Pressure Control Solenoid Valve. Description and Operation
Description line pressure control solenoid valve is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the line pressure. ...

Line Pressure Control Solenoid Valve. Schematic Diagrams
Circuit Diagram ...

See also:

Replacement
1. Remove the front wheel & tire. Tightening torque : 88.3 ~ 107.9N.m(9.0 ~ 11.0kgf.m, 65.1 ~ 79.6lb-ft) ...

Closing the tailgate
To close the tailgate, lower and push down the tailgate firmly. Make sure that the tailgate is securely latched. WARNING Make sure your hands, feet and other parts of your body are safely out o ...

ECM Problem Inspection Procedure
1. TEST ECM GROUND CIRCUIT: Measure resistance between ECM and chassis ground using the backside of ECM harness connector as ECM side check point. If the problem is fo ...