1. |
Check that the red light flickers when the door lock or unlock
button is pressed on the transmitter.
|
2. |
Remove the battery and check voltage if the red light doesn't
flicker.
|
3. |
Insert the battery (A) into the tester (09954-2p100).
|
4. |
Push the test button and If "0.00" is displayed on screen, it
means that the battery voltage is 2V or less.
|
5. |
If "L" is displayed on screen, it means that the battery is low
power and it needs to replace.
|
6. |
To prevent the discharge of electricity, turn the tester power
off.
|
7. |
Replace the transmitter battery with a new one, if voltage is
low power then try to lock and unlock the doors with the transmitter
by pressing the lock or unlock button five or six times.
|
8. |
If the doors lock and unlock, the transmitter is O.K, but if the
doors don't lock and unlock, register the transmitter code, then try
to lock and unlock the doors.
|
9. |
If the doors lock and unlock, the transmitter is O.K, but if the
doors don't lock and unlock, replace the transmitter.
|
Back-up Lamp Switch. Specifications
Specifications
1.
Working voltage: DC 10~15V
2.
Operating force: 3.0kg Max.
3.
Voltage drop: - 0.4V
...
Troubleshooting
Troubleshooting
Problem Symptoms Table
Use the table below to help you find the cause of theproblem. The numbers
indicate the priority of the likecause of the problem. Check each p ...
Manifold Absolute Pressure
Sensor (MAPS). Schematic Diagrams
Circuit Diagram
(M/T)
(A/T)
...